Condition-based maintenance: maintaining on evidence, not the calendar
Back to Knowledge Base
Operations 5 minKnowledge Base

Condition-based maintenance: maintaining on evidence, not the calendar

2026-11-15

Time-based maintenance replaces parts that are still healthy and misses ones that fail early. Monitoring condition lets you act when the equipment tells you to.

The situation

Condition-based maintenance (CBM) uses measured condition (vibration, oil analysis, thermography, performance) to schedule work when degradation is detected, instead of at fixed intervals. ISO 17359 sets out how to set up a condition monitoring programme.

Why condition matters

Many failures do not follow a neat time pattern. Replacing parts on a calendar can waste effort and even introduce faults. Condition monitoring detects deterioration early so work can be planned before failure.

Diagram: Condition-based maintenance
Figure: Atticus Energy, generic illustration.

Common techniques

  • Vibration analysis for rotating equipment.
  • Oil analysis for wear and contamination.
  • Thermography for electrical and insulation problems.
  • Ultrasonic thickness and acoustic monitoring for static equipment.
  • Process performance trends such as efficiency and pressure drop.

Choosing where to apply it

Use it on equipment where failure is costly or unsafe and where there is a detectable warning period before failure. Combine with reliability-centred maintenance to set strategy by failure mode.

Making it work

  • Clear alarm limits and response actions.
  • Data reviewed by someone who can act.
  • Findings linked to work orders in the maintenance system.
  • Feedback to confirm that predictions were right.

Pitfall

Collecting data without acting on it. A monitoring programme is only as good as the decisions it triggers.

Key Takeaways

  • Match strategy to failure pattern and consequence.
  • Condition monitoring needs a detectable warning period.
  • Link findings directly to work orders.
  • Data without action adds cost, not value.

How Atticus helps

We review maintenance strategies, set up condition monitoring for critical equipment and link findings to planning and spares.

Real-world examples

Illustrative scenario

bearing failure caught early

Vibration trending on a pump showed rising bearing defect frequencies. The bearing was replaced in a planned window, avoiding a seal failure and a hydrocarbon leak.

Documented incident

Husky Energy Superior refinery — CSB (2018)

Erosion of a safety-critical slide valve at Husky Superior went undetected until it contributed to an explosion. This shows the value of monitoring the condition of equipment that acts as a barrier.

Read the investigation / source

If you get it wrong

  • Unplanned failures and secondary damage.
  • Over-maintenance with induced failures.
  • Safety-critical degradation going unnoticed.
  • Higher spares and labour costs.

Relevant standards

Links go to the publisher's official page (ISO, IEC, BSI, API, NFPA, HSE and others). Most standards must be bought from the publisher.

Further reading

Take this briefing with you